Relay output 3 parameters, Relay output 4 parameters – Despatch Protocol 3 Modbus Communications User Manual

Page 18

Advertising
background image

A

BOUT

T

HIS

M

ANUAL

Modbus Programming Manual

18

Version 2

Copyright © 2012 by Despatch Industries.

All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any means
including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and retrieval systems without
the written permission of Despatch Industries, unless for purchaser's personal use.




2.2.3. Relay Output 3 Parameters

Parameter
Name

Modbus
Address
(Dec)

Modbus
Address
(Hex)

Access
R/W

Notes

Usage

2186

0x088A

R/W

Value

Usage

0

None

1

Alarm 1

2

Alarm 2

3

Alarm 3

4

Alarm 4

5

Alarm 5

6

Event 1

7

Event 2

8

Event 3

9

Event 4

10

Event 5

11

Cycle Complete

12

Profile Running

13

Or of Alarms

14

Alarm and Events

Alarm Selection

2188

0x088C

R/W

Value

Selection

0

Alarm 1 or Alarm 2

1

Alarm 1 or Alarm 2 or Alarm 3

2

Alarm 1 or Alarm 2 or Alarm 3 or
Alarm 4

3

Alarm 1 or Alarm 2 or Alarm 3 or
Alarm 4 or Alarm 5

Event Alarm
Selection

2190

0x088E

R/W

Value

Selection

0

Alarm 1 or Event 1

1

Alarm 2 or Event 2

2

Alarm 3 or Event 3

3

Alarm 4 or Event 4

4

Alarm 5 or Event 5


2.2.4. Relay Output 4 Parameters

Parameter
Name

Modbus
Address
(Dec)

Modbus
Address
(Hex)

Access
R/W

Notes

Usage

2205

0x89D

R/W

Value

Usage

0

None

Advertising