2.5

95-8657

2

speciFicatiOns

ATX10 and AC100

OpeRATing VOlTAge—

24 Vdc nominal; Operating range is 9 to 30 Vdc.

Um=250 V (Intrinsic Safety Rating).

pOweR COnSumpTiOn—
AC100: 1.25 watts @ 9 Vdc

1.25 watts @ 24 Vdc

1.25 watts @ 30 Vdc.

ATX10: 0.75 watts @ 9 Vdc

1.25 watts @ 24 Vdc

1.75 watts @ 30 Vdc.

TempeRATuRe RAnge—

Operating: –55°C to +75°C (–67°F to +167°F)

Storage:

–55°C to +85°C (–67°F to +185°F).

HumiDiTy—

5 to 95% RH, non-condensing (Det-Tronics verified).

ingReSS pROTeCTiOn—

IP66, NEMA/Type 4X.

COnDuiT enTRieS—

3/4” NPT or M25.

enClOSuRe mATeRiAl—

316 stainless steel, electropolished.

SHipping weigHT—

AC100:

6.2 pounds (2.8 kilograms).

ATX10:

11.5 pounds (5.2 kilograms).

DimenSiOnS—

See Figure 1.

wARm-up—

Upon power-up, device performs self-test and

initialization procedures, then automatically enters

normal operating mode.

wARRAnTy—

3 years.

CeRTiFiCATiOn—

For complete approval details, refer to the appropriate

Appendix:

FM

APPROVED

®

Appendix A - FM

Appendix B - CSA

Appendix C - ATEX

Appendix D - IECEx

Appendix E - Maritime

SIL Approval - IEC 61508

Certified SIL 2 Capable.

For specific information regarding SIL, refer to the

Safety Reference Manual (form 95-8658) for details.

eleCTRO-mAgneTiC COmpATibiliTy—

EMC Directive 2004/108/EC
Emissions: EN61000-6.3

EN61000-6.4
Immunity: EN61000-6.1

EN61000-6.2

AC100 only

ACOuSTiC—

Dynamic Range: 40 to 139 dB
Ultrasonic Band: 24 individual bands over the

ultrasonic frequency range (20 kHz

to 80 kHz).

SelF-DiAgnOSTiC TeST (AiC)—

Automatic acoustic integrity check performed once

every 10 (factory default) minutes.