INSTALLATION

Clearances and Setting

CLEARANCES

MODEL TYPE

TO COMBUSTIBLE WALL

SIDES

REAR*

Range and Range

Attachments

3" (76mm)

1/2" (13mm)

Broiler with Range

6” (152mm)

1/2” (13mm)

* Rear clearance for convection oven base models is

2” (51mm).

Proper placement of the range will ensure operator
convenience and satisfactory performance. Adequate
clearance must be provided for servicing, ventilation and
proper operation. The range must be kept free and clear of
combustible material.

Legs

All units are shipped with N.S.F. approved legs. These legs
must be installed to provide a minimum clearance of 6”
between the floor and bottom of the unit in order to meet
National Sanitation Foundation requirements.

1. Locate unit in its final position.

2. Raise the rear and block it. Insert the bullet foot into the

leg cone. Tap with mallet until the bullet foot seats up to
the collar. Unit may now be leveled by adjusting hex head
portion of the bullet foot. Repeat for all four legs.

Electrical Connections

Before attempting the electrical connection, the rating
plate should be checked to ensure that the unit’s electrical
characteristics and the supply electrical characteristics agree.

The Garland 36E series complies with the standards CSA
C222 no. 109-latest edition, the UL197-latest edition and the
NSF #4-latest edition. The installation & connection of this
appliance must comply with the current codes. In Canada-
the Canadian Electrical Code Part 1 and in the USA-The
national Electrical Code.

1. Switch panel size.

2. Overload

protection.

3. Wire

type.

4. Wire

size.

5. Temperature limitations of the wires.

6. Method of connection (Cable, Conduit, etc.)

Wiring Diagram

IMPORTANT: Input voltage and phasing must match the
units voltage and phasing.

A wiring diagram is attached to the main back of each unit.
Visually check all electrical connections. Energize electric
service to units. The range is wired standard for three phase
connections. If it is necessary to change to single phase,
please refer to wiring diagrams. Service and unit voltage
must agree. Unit rating plate is located behind the lower
front panel.

Circuit Breakers and Fuses

Heavy duty circuit breakers and fuses are provided to assure
you many years of safe trouble-free operation. They are
located behind the lower front panel.

Garland

Terminal Bock
Located behind
Panel.

Circuit
Breakers

Fuses