INFICON SKY CDGxxxD (Profibus) User Manual

Page 43

Advertising
background image

tira54e1-a (2009-01) CDGxxxD.cp

43

This parameter contains the following information:

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

Byte

0

0 0 0 0 0 0 0 NT

Byte

1

0 0 0 0 0 0

EW

0


• NT = Not At Temperature

This bit is set to "1" as long as the specified nominal sensor temperature is not
reached.

• EW = Electronics Warning

This bit is set to "1" if a Temperature Sensor error occurs.

This parameter contains the nominal temperature in degrees centrigrade (Celsius)
to which the sensor warms up.

This parameter defines a customer specified offset which will be added to the
Offset-A value from the Zero-Adjust Service in terms of the currently selected data
type (ID 21) and data unit (ID 22).

This parameter defines the filter function of the basic device.

Filter

Description

0 Dynamic

1 Fast

2 Slow

3…255 Reserved


12.1.4 Sensor Warning (ID 104)

12.1.5 Sensor

Temperature

(ID 105)

12.1.6 Offset (ID 201)

12.1.7 Filter (ID 202)

Advertising