Detent lever (lowering control) valve adjustment – Kinze 3700 Front Folding Planter Rev. 7/14 User Manual

Page 127

Advertising
background image

TM

Model 3700

M0233-01

Rev. 10/11

5-31

Lubrication and Maintenance

deTenT Lever (LOwering COnTrOL) vaLve adJUSTMenT

Center of planter should drop until toolbar is level and then entire planter should lower evenly when lowering planter
for field operation from transport position if detent lever valve is correctly adjusted.

Detent lever valve

Cam

Front

Pivot shaft

2. Raise planter to fully raised position. With cam positioned as shown, adjust detent lever (lowering control) valve

in its mounting slots so there is 1/16" gap between stainless bushing and cam. Lower edge of cam must be above
pivot point of stainless bushing.

nOTe: while lowering planter, center cylinders should begin to retract while wing cylinders stay extended.
when toolbar becomes level, large radius of cam should cause arm to depress plunger on detent lever valve
allowing wing cylinders to start retracting.

3. Lower planter. If center of planter drops lower than wings, loosen set screws and rotate cam clockwise. If wing

cylinder begins to retract too early and wings drop lower than center of planter, rotate cam counterclockwise.
Adjust cam with planter in raised position.

4. After final adjustment, remove one set screw and drill a depression in cam activator shaft with a ¼" drill bit.

Reinstall set screw and repeat with second set screw. This prevents cam from slipping on pivot shaft.

1. Raise planter to field turn around position and check toolbar height is 39"-41". Adjust following procedure for

stroke limiter valve adjustment. Stroke limiter (height stop) valve must be correctly adjusted prior to adjusting
detent lever (lowering control) valve.

planter fully raised

planter lowering - toolbars level

Plunger

Detent lever valve

Cam

Cam

Stainless

bushing

1/16

" gap

Direction of travel

Clockw

ise

Clockw

ise

Advertising