Kinze 3700 Front Folding Planter Rev. 7/14 User Manual

Page 170

Advertising
background image

M0233-01

Model 3700

6-8

Rev. 10/11

TM

Troubleshooting

Seed MeTer (edgevaC) - Continued

prObLeM

pOSSibLe CaUSe

SOLUTiOn

Not planting seed.

(Continued)

Seed baffle (If Applicable) not allowing seed

flow due to bridging of seed.

Mix talc thoroughly to coat all seeds. Remove

seed baffle. Row Unit Operation section.

60 cell soybean disc not filling properly due to

excessive RPM.

Replace with 120 cell soybean disc.

High seed count.

Wrong transmission setting.

Change transmission to desired rate.

High vacuum.

Adjust vacuum level to appropriate level.

Wrong seed disc.

Replace seed disc.

Singulator brush setting not aggressive enough. Adjust singulator brush.
Worn singulator brush.

Inspect brush and replace as required.

Seed leaking past wall brush.

Inspect wall brush condition and installation.

Replace as necessary.

Faulty vacuum gauge.

Check gauge line for dirt/obstruction.

Repair/replace vacuum gauge.

Poor seed spacing.

Obstruction in seed tube.

Clean seed tube.

Dirty/damaged seed disc.

Inspect seed disc for damage, foreign material

in orifices or seed treatment buildup in

recesses. Clean or replace.

Wrong vacuum setting.

Adjust vacuum to appropriate level.

Excess foreign material in seed.

Inspect and clean meter and seed discs.

Use clean, undamaged seed.

Incorrect singulator brush setting.

Adjust singulator brush to appropriate setting.

Inconsistent driveline.

Inspect drive components for rust,

misalignment, worn or damaged parts.

Replace/repair as required.

Toolbar not level or wrong height.

Adjust hitch to level toolbar and row units.

Planting too fast for conditions.

Reduce speed.

Rough field conditions.

Reduce speed.

Irregular seed

population.

Driving too fast.

Reduce speed.

Drive wheels slipping.

Reduce speed. Decrease row unit down

pressure spring settings.

Unable to achieve

desired vacuum level.

Tractor hydraulic flow set too low.

Increase flow to fan motor.

Incorrect hydraulic connections.

Check all hydraulic connections and hose

routings.

Damaged fan components.

Inspect motor and impeller for wear/damage

and repair/replace as necessary.

Vacuum hose pinched/kinked/blocked.

Inspect air lines for any damage or obstruction.

Clean air lines and manifold by removing end

cap from manifold and running fan at high

speed.

Vacuum hose loose/disconnected.

Inspect and reattach all air hoses.

Tractor not producing required hydraulic flow/

pressure.

Have tractor serviced by qualified technician.

Dirt in vacuum gauge line.

Check gauge line for dirt/obstruction and clean.

Advertising