Safety information, Front, Transmission layout – Landoll BPSB6 Till-N Seed User Manual

Page 13: Seed rate calibration

Advertising
background image

SAFETY INFORMATION

1-9

Figure 1-7: Decals (2 of 2)

CALIBRATION CHART

P/N 3P076

TRANSMISSION LAYOUT

P/N 3P160

SEED DRIVE

DISCONNECT

PIN - FRONT BOX

LEFT END VIEW OF MACHINE

5/8" HEX FOR

FRONT BOX

CALIBRATION

TURN CW

5/8" HEX FOR

REAR BOX

CALIBRATION

TURN CCW

FRONT ROTOR AXLE

HIGH

RANGE

MID

RANGE

LOW

RANGE

19T DRIVER

23T DRIVEN

23T DRIVEN

37T DRIVEN

13T DRIVER

10T DRIVER

CALIBRATION TROUGH:

SEEDING POSITION

SEED DRIVE

DISCONNECT

PIN - REAR BOX

VIEW FROM INSIDE OF LEFT END PLATE

CALIBRATION TROUGH:

COLLECTION POSITION

TRANSMISSION LAYOUT

3P160 FOR TILL 'N SEED

3P076 FOR TILL 'N SEED

SEED RATE CALIBRATION

PLACE CALIBRATION TROUGH IN COLLECTION POSITION OR PLACE TARP UNDER

FRONT OF MACHINE. REFER TO SEED CHARTS ON THE SEED BOX COVERS TO

DETERMINE INITIAL SEED METER SETTINGS. IF YOU NEED TO ADJUST SEED

METERS FOR REDUCED OUTPUT WHILE THEY ARE FILLED WITH SEED, THE SEED

METER SHAFT MUST BE TURNED WHILE MAKING THE ADJUSTMENT.

FRONT SEEDBOX

1. IDENTIFY LOWEST TRANSMISSION RANGE EXPECTED TO ACHIEVE SEED RATE

2. ADJUST SEED METER SETTING

3. REMOVE SEED DRIVE DISCONNECT PIN - FRONT BOX

4. PRIME METERS: TURN 5/8" HEX FOR FRONT BOX CALIBRATION CW UNTIL ALL

METERS ARE DISCHARGING SEED. EMPTY CALIBRATION TROUGH OR TARP

5. COUNTING REVOLUTIONS, TURN THE 5/8" HEX CW TO METER OUT SEED

6. WEIGH THE SEED

7. CALCULATE SEED RATE:

LBS OF SEED x A 252 (LOW RANGE)

SEED RATE (LBS / ACRE) = ------------------------------ A= 528 (MID RANGE)

CALIBRATION REVS 771 (HIGH RANGE)

8. ADJUST METERS AND RE-CALIBRATE AS NECESSARY

9. ENSURE TRANSMISSION IS SET UP FOR PROPER SEEDING RANGE

10. RE-INSTALL SEED DRIVE DISCONNECT PIN - FRONT BOX

11. RE-INSTALL CALIBRATION TROUGH IN SEEDING POSITION

REAR SEEDBOX

1. ADJUST SEED METER SETTING

2. REMOVE SEED DRIVE DISCONNECT PIN - REAR BOX

3. PRIME METERS: TURN 5/8" HEX FOR REAR BOX CALIBRATION CCW UNTIL ALL

METERS ARE DISCHARGING SEED. EMPTY CALIBRATION TROUGH OR TARP

4. COUNTING REVOLUTIONS, TURN THE 5/8" HEX CCW TO METER SEED

5. WEIGH THE SEED

6. CALCULATE SEED RATE:

LBS OF SEED x 143

SEED RATE (LBS / ACRE) = -------------------------------

CALIBRATION REVS

7. ADJUST METERS AND RE-CALIBRATE AS NECESSARY

8. RE-INSTALL SEED DRIVE DISCONNECT PIN - REAR BOX

9. RE-INSTALL CALIBRATION TROUGH IN SEEDING POSITION

FRONT