3 mounting steps, Mechanical installation – Lenze E94AZPP User Manual

Page 45

Advertising
background image

Mechanical installation

Mounting steps

4

l

45

EDK94ZPP0364 DE/EN/FR/ES/IT 2.1

4.3

Mounting steps

Proceed as follows for the installation:
1. Prepare M5 threaded holes on the mounting plate according to the

mounting grid.

2. Screw the installation backplane onto the mounting plate. Do not yet

tighten the screws.

Use M5 screw and washer assemblies or M5 hexagon socket screws
with washers.

The screw joint in the installation backplane may not jut out more than
7 mm.

3. Repeat step 2 for other installation backplanes, which can be mounted

directly adjacent to one another.

4. Align all installation backplanes.
5. If busbars are used: connect the busbars.
6. Tightly screw all installation backplanes onto the mounting plate.

Tightening torque: 3.4 Nm (30 lb−in).