2 connection plan, E94apne0xx4, Wiring the installation backplane – Lenze E94AZPP User Manual
Page 48: Connection plan, 2 connection plan power supply module
Advertising
![background image](/manuals/565815/48/background.png)
Wiring the installation backplane
Connection plan
l
48
EDK94ZPP0364 DE/EN/FR/ES/IT 2.1
5.2
Connection plan
Power supply module
L3
N
PE
L1
L2
F1...F3
R
B
E94AxxExxxx
E94AZPxxxxx
X109
X110
Z1
E94APNE0xx4
24E GE
X11
E94AZPPxxxx
X109
X110
L1
L2
L3
X111
+UG -UG
L1 L2 L3
X112
Rb1 Rb2
K1
F4
K1
K1
O
I
R
B
J
+
-
3
+
+
SSP94PSP21
Fig. 5−1
Example circuit for installation backplane and DC power supply module
E94APNExxx4
9400 DC power supply module
E94AZPxxxxx
Installation backplane
E94AxxExxxx
9400 axis module
E94AZEX100
DC input module
F1 ... Fx
Fuses
Z1
Mains filter/RFI filter (optional)
K1
Mains contactor
RB
Brake resistor
Alternative: mains connection at the bottom
24 V supply voltage for control electronics according to IEC 61131−2
Advertising