2 connection plan, E94apne0xx4, Wiring the installation backplane – Lenze E94AZPP User Manual

Page 48: Connection plan, 2 connection plan power supply module

Advertising
background image

Wiring the installation backplane

Connection plan

5

l

48

EDK94ZPP0364 DE/EN/FR/ES/IT 2.1

5.2

Connection plan

Power supply module

L3
N
PE

L1

L2

F1...F3

R

B

E94AxxExxxx

E94AZPxxxxx

X109

X110

Z1

E94APNE0xx4

24E GE

X11

E94AZPPxxxx

X109

X110

L1

L2

L3

X111

+UG -UG

L1 L2 L3

X112

Rb1 Rb2

K1

F4

K1

K1

O

I

R

B

J

+

-

‚



3

+

+

SSP94PSP21

Fig. 5−1

Example circuit for installation backplane and DC power supply module

E94APNExxx4

9400 DC power supply module

E94AZPxxxxx

Installation backplane

E94AxxExxxx

9400 axis module

E94AZEX100

DC input module

F1 ... Fx

Fuses

Z1

Mains filter/RFI filter (optional)

K1

Mains contactor

RB

Brake resistor



Alternative: mains connection at the bottom

‚

24 V supply voltage for control electronics according to IEC 61131−2