Wiring the installation backplane – Lenze E94AZPP User Manual

Page 55

Advertising
background image

Wiring the installation backplane

Wiring

Terminal assignment

5

l

55

EDK94ZPP0364 DE/EN/FR/ES/IT 2.1

External brake resistor

Terminal X112
(left part)

Labelling

Description

Rb1
Rb2

External brake resistor

SSP940X112

Terminal data

Max. conductor cross−section

Tightening torque

!

[mm

2

]

[AWG]

[Nm]

[lb−in]

Device sizes 1+2:
flexible
with wire end
ferrule

2.5

12

0.5 ... 0.6

4.5 ... 6.2

PZ0

Device size 3:
flexible
with wire end
ferrule

10

6

1.2 ... 1.5

10.6 ... 13.3

PH1

DC bus

Terminal X111
(right part)

Labelling

Description

+UG
−UG

Alternative option for DC−bus voltage connection
(compatible to 9300 series)

E94ARNE0244: maximum current I

dc

= 50 A

SSP940X111

Terminal data

Max. conductor cross−section

Tightening torque

!

[mm

2

]

[AWG]

[Nm]

[lb−in]

Device sizes 1+2:
flexible
with wire end
ferrule

2.5

12

0.5 ... 0.6

4.5 ... 6.2

PZ0

Device size 3:
flexible
with wire end
ferrule

10

6

1.2 ... 1.5

10.6 ... 13.3

PH1