Commissioning

Connecting the mains voltage

EDK82ZAFIC−001 DE/EN/FR 5.0

58

l

H2 NetzspgZuschalten−unkontroll_Anlauf_FIF

Connecting the mains voltage

)

Note!

If the external voltage supply of the function module is used, switch it on as
well.

ƒ The standard device is ready for operation approx. 1 s after switching on the supply

voltage.

ƒ The controller inhibit is active.
ƒ The green LED at the front of the function module is lit.

Protection against uncontrolled start−up

)

Note!

Establishing communication

For establishing communication via an externally supplied function module,
the standard device must be switched on as well.

ƒ

After communication has been established, the externally supplied module
is independent of the power on/off state of the standard device.

Protection against uncontrolled start−up

After a fault (e.g. short−term mains failure), a restart of the drive is not always
wanted and − in some cases − even not allowed.

The restart behaviour of the controller can be set in C0142:

ƒ

C0142 = 0 (Lenze setting)
– The controller remains inhibited (even if the fault is no longer active).
– The drive starts in a controlled mode by explicitly enabling the

controller: LOW−HIGH edge at terminal 28 (CINH)

ƒ

C0142 = 1
– An uncontrolled restart of the drive is possible.