Setting options via switches, Commissioning – Lenze E82ZAFVC010 User Manual

Page 57

Advertising
background image

Commissioning

Setting options via switches

4

EDK82ZAFVC010 DE/EN/FR 2.0

57

l

H1inbet−reihenfolge einhalten

Setting options via switches

)

Note!

Settings via GDC, keypad or configuration software

Controller address and baud rate can be set by means of GDC, keypad or
configuration software.

For this, DIP switches S7 and S8 must be set to the ON position.

Settings via front switch

The Lenze setting of all switches is OFF.

The controller address and baud rate set via DIP switch will only be active after
restarting the controller.

Switch S9 is ineffective.

The following settings can be easily carried out via the front DIP switch of the function
module:

ƒ Software compatibility of E82ZAFVC / E82ZAFD function module with S10

ƒ Controller address with S1 − S6

ƒ Baud rate with S7 / S8

ON

1

6

2

7

4

3

8

5

9

10

ON

OFF

E82ZAFD005

Fig. 1

Software compatibility setting

Compatibility

S10

E82ZAFVC0xx

OFF

E82ZAFD
For the description of the
function module see the
E82ZAFD Mounting Instructions

ON