Status display, Commissioning – Lenze E82ZAFVC010 User Manual

Page 63

Advertising
background image

Commissioning

Status display

4

EDK82ZAFVC010 DE/EN/FR 2.0

63

l

inbetrieb−statusanzeige AFV0xx

Status display

E82ZAFD101A*

Pos

Status display

Explanation

1

Connection status to basic device (LED, green / red)

OFF

Function module is not supplied with voltage,
external voltage supply is switched off

GREEN

BLINKING

Function module is supplied with voltage but not
connected to the controller.
Reason:
Basic device is

l

switched off

l

is being initialised

l

not available

Constantly ON

Function module is supplied with voltage and is
connected to the basic device

RED

BLINKING

Internal error, Lenze setting has been loaded

Constantly ON

Internal error of the function module

2

Connection status to bus (LED, green / red)

OFF

l

No connection with the master.

l

Function module is not supplied with voltage.

GREEN

BLINKING

Dup_Mac_ID" test phase. Not yet connected to master

(scanner).

Constantly ON

DeviceNet connection completed.

RED

BLINKING

No communication because time limit has been
exceeded

Constantly ON

Critical bus error

Advertising