5 technical data, General data/operating conditions, Technical data 64 – Lenze E82ZAFVC010 User Manual

Page 64: 5technical data

Advertising
background image

5

Technical data

General data/operating conditions

EDK82ZAFVC010 DE/EN/FR 2.0

64

l

H1daten−abmess

5

Technical data

General data/operating conditions

Field

Values

Order designation

E82ZAFVC010

PT version

Communication medium

DIN ISO 11898

Communication profile

DeviceNet

Network topology

Line terminated at both ends (R = 120 Ohm)

Max. number of participants

63

DeviceNet participant

Slave

Baud rate [kbit/s]

125, 250, 500

Max. possible bus cable length

depending on the cable used, see

^ 55

External voltage supply

see

^ 52

Type of protection

IP20

Ambient temperature

Operation:

−20 °C ... +60 °C

Transport:

−25 °C ... +70 °C

Storage:

−25 °C ... +60 °C

Climatic conditions

Class 3K3 according to EN 50178 (without condensation,
average relative humidity 85 %)

Degree of pollution

EN 50178, pollution degree 2

X3.1/

V+

External DC voltage supply for the function module:
+24 V DC ±10 %, max. 80 mA

The current flowing via terminal V+ when looping through the supply voltage to other
bus devices must not exceed 3 A.

X3.2/

7

Reference potential 1

39

Reference potential 2 of controller inhibit (CINH) at X3.2/28

28

Controller inhibit

l

Start = HIGH (+12 V ... +30 V)

l

Stop = LOW (0 V ... +3 V)

Input resistance: 3.3

k

W

20

+ 20 V internally for CINH, reference potential 1, load capacity: I

max

= 30 mA

Advertising