Mechanical installation – Lenze E82ZMFBC001 User Manual

Page 47

Advertising
background image

Mechanical installation

Wall mounting

4

EDK82ZMFBC-001 DE/EN/FR 7.0

47

H1_MechINS-E82ZMFB_BusIO

Mounting

1. Mount the housing shell to the mounting plate using the 2 self-tapping screws

5 × 18.

2. Mount the cable glands M16 using a 10 mm thread length.
3. Screw the fixing frame for the fieldbus function module into the housing shell using

2 self-tapping screws 3 × 10.

4. Press the fieldbus function module into the fixing frame until it snaps into place.
5. Remove the cover of the terminal strip.
6. Wire the fieldbus function module.

– Remove approx. 10 cm of the cable sheath.

– Connect the shield to the shield sheet using the cable tie.

– Wire the fieldbus function module (see corresponding Mounting Instructions).

Terminal 28 (controller inhibit) of the fieldbus function module

isinactive.Controller

is inhibited via terminal 28 of the bus-I/O function module.

E82ZMFB006

7. Mount motec carrier housing

– Break out holes at the predetermined breaking points

.

– Insert 2 screws M5 × 20 through holes

 and 2 self-tapping screws 5 × 55 through

holes

.

– Screw motec carrier housing onto the housing shell.

Advertising