5 electrical installation – Lenze E82ZMFBC001 User Manual

Page 52

Advertising
background image

5 Electrical installation

Wiring

EDK82ZMFBC-001 DE/EN/FR 7.0

52

H1_E_INST-INS_Klemmenbeleg

X3/

Signal

type

Function

(Lenze setting: bold print)

Level

(Lenze setting: bold print)

62

Analog

output

Output frequency

0 … +6 V

0 … +10 V

1)

7

-

GND1,

Reference potential for analog signals

-

8

Analog

input

Input for actual value or setpoint

Switch over the range with the DIP switch and in C0034:

z

Voltage signal

0 … +5 V

0 … +10 V

-10 … +10 V

2)

z

Current signal

0 … +20 mA

+4 … +20 mA

+4 … +20 mA (open-circuit

monitored)

9

-

Internal, stabilised DC voltage source for the

setpoint potentiometer

+5.2 V

20

-

Internal DC voltage supply for control of digital

inputs and outputs

+20 V ±10 % (ref.: X3/7)

28

Digital

inputs

Controller inhibit (CINH)

1 = enable

E1

3)

Activation of JOG frequencies

JOG1 = 20 Hz

JOG2 = 30 Hz

JOG3 = 40 Hz

e1

E2

JOG1

1

0

E2

3)

JOG2

0

1

JOG3

1

1

E3

DC-injection brake (DCB)

1 = DCB

E4

Change of direction of rotation

CW/CCW rotation

E4

CW

0

CCW

1

39

-

GND2,

Reference potential for digital signals

-

A1

Digital

output

Ready for operation

z

internal supply:

z

external supply:

0 … +20 V

0 … +24 V

59

-

DC supply for X3/A1

z

internal (bridge to X3/20):

z

external:

+20 V

+24 V

1)

Output level 0 … +10 V: Adapt offset (C0109/C0422) and gain (C0108/C0420)

2)

Adjust offset (C0026) and gain (C0027) separately for each function module ...

- after replacing the function module or the basic device.

- after loading the Lenze setting.

3)

Frequency input alternatively 0 … 10 kHz single-track or 0 ... 1 kHz two-track, config. via C0425

Advertising