5.14 Motor

corYnection

‚~

screened

motor

cable

three-phase

motor 3

—

Ihe

nominal

motor

voltage

is

normally selected such that

it

corresponds to the available

nominal

mains voltage

e.g.

380V motor

at 380V mains

460V motor

at

460V mains

—

lt

the nominal

mains voltage

exceeds

the nominal motor

voltage,

the

inverte.r‘s

output

characteristic can be pro—

grammed as

described urider

turietion code

10.

—

Switching of

the phases

is

only

permissible with the circuit

as

described under polnt

5.13.

(*)

Valid

tor industrial

plants

and factories which must have

levels

ot radio

interference

suppression in

compliance

with

VDE 0871.

lt necessary,

please

consult the supplier.

5.15 Connection

of

braking resistor(s

)

—

Application:

Short braking

times

with

large masses.

—

The energy produced in the

„gene-

rator

rnode“

is

fed into the

DC

link circuit

ot the Inverter

and results

in

an

iricrease of

the

DC

link voltage

and current,

when

operating without

a braking

chopper.

The inverter sets TRIP.

Fault

indication:

OC

2 or OU.

—

Using a braking

resistor

or acti—

vating

the internal

braking

chopper

(See tiinctlon

code

23) causes the

excessive energy to be

dlssipated

as

heat.

The ~?D(~cifiedbrake resistor~

~re

1.sted in

the table on

page

21.

*

?or settir.

ot

the release

current

see table

an page

21).

brake

resistor