Installation

instructions

The controller

should be

fitted vertically

with the terminals

located

at

the bottom.

Ensure that there

is

a

free space

of

±:LOOin~

at

the top and bottain,

and 50 mm

at

the sides

in

order

to

inaintain the flow of

air

tI~xrough the heat

sink

and controller.

The

maxrmmm

ambient temperature must not exceed 400C.

In case

of an

earth

circuit fault,

the mains

choke

limits

the current

rise and

improves the ~nains current factor.

The 7800

inverter series

inust only be operated with specif led mains

choke

and sexni-conductor

fuses

(see paint

10./il.).

5.

Connectinc~

instructions

5..l External

set—value

5..l.1

Usinc~ potentioxneter

(-)

+10V

Corrnect the enclosed
potentiometer 1 kfl

linear

(part no..:

304

651)

to

terminals

11,

12,

13,

ensuring that the wiper

of

the potentiometer

is

connected

to

l2~

5.1.2

Connect the external master voltage
source to terminals

11

and 12.

Umaster max

=

10

V

For

a

master

voltage

of

0 to—lOV the wire

link

~

UmastermaxiOV

must be

connected

as

shown

in

the

figure.

5..l..3

Usinq~ current

loop

control

~f~B3Ocf12

Connect

the

external

current

source

between terminals

11

and Cl.

‚master

=

4

~-

20mA

-

For giving speed

control

froln

a 0 to

2OmA current

signal,

ensure

that

a 511 fl

resistor

(‚-x=~t ;o.

225

?D2)

is

c~nm-.ccted

-~

—.

master