1_put current (%) – Lenze Range 7800 User Manual
Page 24
![background image](/manuals/566113/24/background.png)
checked:
19.04.89
MB
33.0831
GB
page:
23
-
Data code 02
The tunctions
are also controlled via the terminal block;
the
„PJJN“
and
„Stop“
keys are not etteative.
The
motor voltage
is
set automatically in the stationary operation.
During accele-
ration and deceleration a motor voltage ot the data code 8
and
tunction code 9
is set.
UM
=100%
fD
-
Data code 03
The
funotions
„RUN“
and
„Stop“
are controlled via the keyboard.
The terminals Xl,
X2,
„Jog“
and „Satt“ da not have any fuziction.
The motor voltage
is set automatically depending on the
rotational tield trequency as described under data code 00.
Function code
20
The opto—coupler output
„012‘
can be
activated
in
case ot
overload
using tunction code 20. The threshold current can be set according
ta the
following table.
Data code
00
01
02
03
04
-T
05
Inverter aut—
non
110
120
130
140
150
1_put current (%)
active
ET4 6/ta