ET4 6/fa

checked:

19.04.89

MB

33.0831 GB

5.5

External

teniperature

switch

Use low-current

contacts

(12V/lOmA)

-

Temperature

swltches

can be

connected

to the terminal

muarked THIR,

in order to supervise

the motor temperature

or monitor

the temperature

of

the external

braking

chopper resistors.

As soon as the contact

is

opened,

the

inverter

switches

to show a

fault

condition.

(This f1lnction

is

selt

holding).

The display

shows code OLl.

5.6 Bxternal

TRIP reset

T

-

RST can

be used to

provide

an

external TRIP reset.

CMjRSTj

switch

59

Use

low-current

contacts

(12V/lOmA)

5.7 Switchinq-

of the acceleration

and deceleration ramp

-

Using the terminal

marked „Saft“

a second common acceleration

and

deceleration

time

can be used.

S6

Use low—current

contacts

(12V/lOm.A)

So!

k

_______

page:

7

79.

S8

1‘