Lenze Range 7800 User Manual
Page 23
ET4
6/ta
checked:
19.04.89
MB
33.0831
GB
page:
22
Function codes
16,
17,
18
In order to avoid machine resonances during acceleration
and
deceleratlon,
due
to the output freguency,
3
trequency notches
ot
1 Hz each can be programxned in. The parameter variables are
in Hz.
No tactory
setting
ot trequency
notches
set volue
Furiction
code
19
The control mode and the motor voltage control
can be set uslng
fu.nction code 19,
vla keyboard or terminals.
(Factory setting 00).
-
Data code 00
The tunctions are controlled via the terminal block connectians;
the „P.UN“
and
„Stop“
keys an the keyboard are not ettective.
The
motor voltage depends on the rotational tield frequency as
set via function codes
09 and
10.
-
Data code 01
The furictions
are also controlled via the terminal block
connections;
the
„RUN“
and „Stap“
keys are
not etfective.
The motor voltage
is
set depending on the rotational
field trequency and the necessary torque.
0
voltage control range