Lenze Range 7800 User Manual

Page 23

Advertising
background image

ET4

6/ta

checked:

19.04.89

MB

33.0831

GB

page:

22

Function codes

16,

17,

18

In order to avoid machine resonances during acceleration

and

deceleratlon,

due

to the output freguency,

3

trequency notches

ot

1 Hz each can be programxned in. The parameter variables are

in Hz.

No tactory

setting

ot trequency

notches

set volue

Furiction

code

19

The control mode and the motor voltage control

can be set uslng

fu.nction code 19,

vla keyboard or terminals.

(Factory setting 00).

-

Data code 00
The tunctions are controlled via the terminal block connectians;
the „P.UN“

and

„Stop“

keys an the keyboard are not ettective.

The

motor voltage depends on the rotational tield frequency as

set via function codes

09 and

10.

-

Data code 01

The furictions

are also controlled via the terminal block

connections;

the

„RUN“

and „Stap“

keys are

not etfective.

The motor voltage

is

set depending on the rotational

field trequency and the necessary torque.

0

voltage control range

Advertising