Function
code 24
This function allows
tor limiting the motor current in the starting
phase.
lt
the
motor current is higher than the preset maximum current
the Inverter output trec~uency is held constant until the current
demand
of the motor is smaller than the inverter‘s preset maximum
current value.
At this point,
the acceleration phase is
once again
resuned.
rD
1malcr
f
The data code tor the maximum inverter output current,
which must not
be exceeded during the starting phase, can be calculated as follows:
starting
current
(%)
=
maximum inverter out~ut current A ~ 100
%
nominal
inverter current A
The coded input ot the starting current is achieved according to
the following table: