ET4 6/fa

checked:

19.04.89

MB

33.0831

GB

page:

12

6.

Display and operating unit

1

2

(

50 ~0 80 ~Q)0O%

40

___

30/

—~;

1

A

lOj

2O2E~

Dl

~

SET

5~LEI

STD~

31

4

1

6

7

8

9

1.

Output trequency

in percent

(related to

the maximum

frequency).

2.

7-segioent display tor output tre~uency/current
tor normal

operation,

or

alternatively,

tor the input

parameters during programming.

3.

Selection key tor operating

mode or

program mode.

(S2=0)

4.

Switching key tor motor current

display or

motor

treguency

during normal

operation or key

tor selection

Dt

each

function

code during programlning mode.

5.

~ey

tor storing new parameters

in

the program mode

and

also tor storing the rotational tield trequency,

when

set—value is entered via the keyboard.

6.

Keys tor parameter setting when in the program mode,

or

for

trequency setting when the set trequency is entered via
the keyboard.

7.

For stopping

the motor with internal control.

8.

For starting the motor with internal control.

9.

Key tor TRIP reset.