Electrical installation, Power terminals connection to the dc bus (+u – Lenze ECSEAxxx User Manual

Page 100

Advertising
background image

Electrical installation

Power terminals
Connection to the DC bus (+U

G

, −U

G

)

5

l

100

EDKCSEX064 DE/EN/FR 6.0

L3

N

L1

L2

Z1

K1

L1

L2

L3

PE

X21

+UG

+UG +UG

-UG

-UG

-UG

PE

PE

PE

X22

X23

Off

On

+UG

BR1

BR0

M

3~

R

T1

T2

X6

...

J

2

6

K1

0

U

V

W PE

X24

BD1 BD2

X25

X7

"

"

+

"

"

+UG +UG

-UG

-UG

PE

PE

X23

M

3~

R

J

2

6

0

U

V

W PE

X24

BD1 BD2

X25

X7

+

"

"

"

"

F4

F1...F3

"
"

ECSxS/P/M/A...

ECSxE...

ECSxS/P/M/A...

ECSXA011

Fig. 5−2

Power system: ECSxE power supply module with ECSxS/P/M/A axis modules

"

HF−shield termination by large−surface connection to functional earth (see
Mounting Instructions for ECSZS000X0B shield mounting kit)

Twisted cables

K1

Mains contactor

F1 ... F4

Fuse

Z1

Mains choke / mains filter, optional

J

KTY thermal sensor of the motor

0

System cable for feedback˘

Advertising