Electrical installation

Wiring of the feedback system
Encoder connection

5

l

128

EDKCSEX064 DE/EN/FR 6.0

SinCos encoders and SinCos absolute value encoders with Hiperface

Features

Input/output frequency:

0 ... 200 kHz

Internal resistance (R

i

):

221

W

Offset voltage for signals SIN, COS, Z:

2.5 V

ƒ

The differential voltage between signal track and reference track must
not exceed 1 V

± 10 %.

ƒ

The connection is open−circuit monitored (fault message "Sd8")

ƒ

For encoders with tracks sine, sine and cosine, cosine:

Assign RefSIN with sine.

Assign RefCOS with cosine.

ƒ

For SinCos absolute value encoders with Hiperface, the serial interface (RS
485) is available instead of the zero track (Z track).

SIN

COS

0.5 V

0.5V

RefSIN

RefCOS

2.5 V

2.5 V

0 V

0 V



X8

5

1

9

6

SIN

V

CC

GND

Z

R1 (+KTY)

R2 (-KTY)

1

2

3

4

5

6

7

8

9

COS

< 50 m

RefCOS

RefSIN

Z

KTY

ECSXA023

Fig. 5−14

Connection of SinCos encoder



Signals in case of clockwise rotation
Cores twisted in pairs

Assignment of plug connector X8: Sub−D 9−pole

Pin

1

2

3

4

5

6

7

8

9

Signal

SIN

RefCOS

(cos)

COS

V

CC

GND

(R2/−KTY)

Z or

−RS458

Z or

+RS485

R1

(+KTY)

RefSIN

(sin)

0.14 mm

2

(AWG 26)

1 mm

2

(AWG 18)

0.14 mm

2

(AWG 26)

Advertising
This manual is related to the following products: