Rated data

3

l

89

EDKCSEX064 DE/EN/FR 6.0

Rated data

Type

Axis module

ECSx

L032

ECSx

L048

ECSx

L064

Output power 400 V mains

S

rated

[kVA]

8.3

11.2

13.2

Data for operation with upstream power supply
module on mains voltage

U

mains

[V]

400

480

400

480

400

480

DC−bus voltage

V

DC−bus

[V]

15 ... 770

DC−bus current

I

DC−bus

[A]

15.6

12.5

20.9

16.8

24.5

19.6

Rated output current at 4 kHz
(causes a heatsink temperature of 70°C at an
ambient temperature of 20°C)

I

r

[A]

12.7

10.2

17.0

13.6

20.0

16.0

Rated output current at 8 kHz

(at an ambient

temperature of 20°C it causes a heatsink
temperature of 70°C)

1)

I

r

[A]

8.5

6.8

11.3

9.0

13.3

10.6

Max. output current
(acceleration current)

I

max

[A]

32.0

48.0

64.0

Continuous current at standstill

2)

(holding current at 90°C, 4 kHz)

I

0,eff 4 kHz

[A]

16.0

12.8

23.0

18.4

27.0

21.6

Short−time standstill current
(holding current at 90 °C, 4 kHz)

2)

I

0,eff 4 kHz

[A]

18.1

27.2

36.3

Short−time standstill current
(holding current at 70 °C, 4 kHz)

2)

I

0,eff 4 kHz

[A]

24.0

36.0

48.0

Short−time standstill current
(holding current at 70 °C, 8 kHz)

2)

I

0,eff 8 kHz

[A]

12.1

18.1

24.2

Power loss (operation with
rated current at 4 kHz / 8 kHz)

Total

P

loss

[W]

144.5

166.5

199.0

Inside the

device

27.5

34.5

41.0

Heatsink

117.0

132.0

158.0

Max. output frequency

f

out

[Hz]

600

Mass

m [kg]

approx. 2.4

approx. 3.3

1)

If the heatsink temperature reaches 70°C, the switching frequency automatically changes to
4 kHz.

2)

The indicated temperature is the measured heatsink temperature (C0061).

L

Application software:

S = Speed & Torque

P = Posi & Shaft

M = Motion

A = Application