Electrical installation – Lenze ECSEAxxx User Manual

Page 130

Advertising
background image

Electrical installation

Wiring of the feedback system
Digital frequency input/output (encoder simulation)

5

l

130

EDKCSEX064 DE/EN/FR 6.0

Wiring

ƒ

1 slave on the master:
Wire master and slave to each other directly via interface X8.

B

GND

Z

1
2

3
4
5
6
7
8
9

1
2

3
4
5
6
7
8
9

A

< 50 m

A

B

Z

A

A

B

Z

B

Z



X8

(ECS-Slave)

X8

(ECS-Master)

5

1

9

6

ECSXA029

Fig. 5−15

Connection of the master frequency input/output X8 (master

« slave)



Signals for clockwise rotation
Cores twisted in pairs

Assignment of plug connector X8: Sub−D 9−pole

Pin

1

2

3

4

5

6

7

8

9

Input signal

B

A

A

˘

GND

Z

Z

˘

B

Output signal

B

A

A

˘

GND

Z

Z

˘

B

0.14 mm

2

(AWG 26)

1 mm

2

(AWG 18)

0.14 mm

2

(AWG 26)