Thermal motor monitoring

2

l

77

EDKCSEX064 DE/EN/FR 6.0

Behaviour of the I

2

x t monitoring

Condition

The I

2

x t monitoring is deactivated.

C0066 is set = 0 % and
MCTRL−LOAD−I2XT is set = 0.00 %.

When C0120 = 0 % and C0127 = 0 %, set
controller inhibit.

I

2

x t monitoring is stopped.

The current value in C0066 and at the
MCTRL−LOAD−I2XT output is frozen.

When C0120 = 0 % and C0127 = 0 %, set
controller enable.

I

2

x t monitoring is deactivated.

The motor load is displayed in C0066.

Set C0606 = 3 (off) and C0127 > 0 %.

)

Note!

An error message OC6 or OC8 can only be reset if the I

2

x t load falls

below the set trigger threshold by 5 %.