4

l

36

EDKVF93−05 EN 2.0

Remedy

Cause

Error

Error number

x = 0: TRIP
x = 1: Message
x = 2: Warning

Display

H10

x110

Sensor fault −
heatsink
temperature

Sensor of the heatsink temperature
detection indicates undefined values

Contact Lenze

l

Fault message can only be reset by
mains switching

H11

x111

Sensor fault −
temperature inside
the device

Sensor of the internal temperature
detection indicates undefined values

Contact Lenze

l

Fault message can only be reset by
mains switching

ID1

x140

Error during motor
data identification

l

No motor connected

l

Stator resistance too high

l

Controller inhibited externally

l

Check motor connection

l

Check motor data entry

l

Enable controller and repeat motor
data identification. The controller
enable must be pending
continuously until the end of the
identification process.

ID2

x141

Error during motor
data identification

Motor too small

l

Check entered motor data
– When setting parameters with

Global Drive Control, use the input
assistant for motor data

l

The measurements for the inverter
error characteristic and the stator
resistance are correct (save measured
values in C0003). In the operating
mode U/f characteristic control, the
motor data identification can be
completed.

Controller inhibited externally

Enable controller and repeat motor data
identification. The controller enable
must be pending continuously until the
end of the identification process.

LP1

x032

Motor phase
failure

A current−carrying motor phase has
failed

l

Check motor

l

Check supply cables

The current limit is set too high

Set a lower current limit value under
C0599

This monitoring is not suitable for field
frequencies >480 Hz and synchronous
servo motors

Deactivate monitoring with C0597= 3

LU

x030

Undervoltage

DC bus voltage is smaller than the value
set under C0173

l

Check mains voltage

l

Check supply module

NMAX

x200

Maximum system
speed exceeded
(C0596)

Active load too high

Check drive dimensioning

Drive is not speed−controlled, torque
excessively limited

If required, increase torque limit

Current speed is detected incorrectly

Check parameter setting of the
incremental encoder (C0025)

OC1

x011

Overcurrent
(motor current >
2.25−fold rated
controller current,
hardware
monitoring)

Short circuit/earth fault

l

Remove cause of short circuit/earth
fault

l

Check motor and cable

l

If required, measure the insulation
resistance

Capacitive charging current of the
motor cable too high (especially with
lower powers)

Use shorter or low−capacitance motor
cable

Acceleration/deceleration times too
short in proportion to the load (C0012,
C0013, C0105)

l

Increase the gain (P component) of
the current controller (C0075)

l

Reduce integral−action time (integral
action component) of the Imax
controller (C0076)

Advertising