Function library, Acceleration, deceleration, braking, stopping – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual
Page 100

Function library
Acceleration, deceleration, braking, stopping
7−29
L
EDB82MV752 EN 5.2
Fail−safe change of the direction of rotation
Link C0410/22 and C0410/23 with one digital signal source each.
If the direction of rotation is changed, the drive brakes along the quick stop ramp (C0105) and
accelerates along the acceleration ramp (C0012) in the other direction or rotation.
Direction of rotation with in−phase connection and HIGH active signal:
Direction of rotation
Signal level at
Notes
C0410/22
(DCTRL1−CW/QSP)
C0410/23
(DCTRL1−CCW/QSP)
CCW rotation
LOW
HIGH
CW rotation
HIGH
LOW
Quick stop
LOW
LOW
Unchanged
HIGH
HIGH
·
During operation: The direction of rotation results
from the signal which was active first.
·
When switching on the mains: The controller
activates quick stop (QSP).
)
Note!
In addition to the free configuration in C0410 you can also use the fixed assignment