Technical data, General data/operating conditions – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual
Page 18

Technical data
General data/operating conditions
3−3
L
EDB82MV752 EN 5.2
Open and closed loop control
Open and closed−loop control methods
V/f characteristic control (linear, quadratic), vector control, torque selection
Switching frequency
optionally 2 kHz, 4 kHz, 8 kHz, 16 kHz
Torque behaviour
Maximum torque
1.8 x M
N
for 60 s
if rated motor power = rated controller power
Setting range
1 : 10
in speed setting range 3 ... 50 Hz, accuracy < 8 %
Torque/speed
characteristic
1.8
2.0
1.0
M/M
N
n [min ]
-1
500
1000
1500
Sensorless speed
control
Minimum output
frequency
1.0 Hz (0 ... M
N
)
Setting range
1 : 50
related to 50 Hz and M
N
Accuracy
± 0.5 %
in speed setting range 3 ... 50 Hz
Smooth running
± 0.1 Hz
Output frequency
Range
− 650 Hz ... + 650 Hz
Absolute resolution
0.02 Hz
Standardised
resolution
Parameter data: 0.01 %, process data: 0.006 % (= 2
14
)
Digital setpoint
selection
Accuracy
± 0.005 Hz (= ±100 ppm)
Analog setpoint
selection
Linearity
± 0.5 %
Signal level: 5 V or 10 V
Temperature
sensitivity
+ 0.3 %
0 ... 60 °C
Offset
± 0 %