Technical data, General data/operating conditions – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual
Page 19

Technical data
General data/operating conditions
3−4
L
EDB82MV752 EN 5.2
Inputs and outputs
Analog
inputs/outputs
with standard I/O
1 input, optionally bipolar
1 output
with application I/O
2 inputs, optionally bipolar
2 outputs
Digital
inputs/outputs
with standard I/O
4 inputs, optionally 1 frequency input, single−track 0 ... 10 kHz / two−track 0...1 kHz; 1 input for controller inhibit
1 output
with application I/O
6 inputs, optionally 1 frequency input, single−track / two−track 0 ... 102.4 kHz; 1 input for controller inhibit
2 outputs, 1 frequency output 50 Hz ... 10 kHz
Cycle times
digital inputs
1 ms
digital outputs
4 ms
analog inputs
2 ms
analog outputs
4 ms (smoothing time:
t = 10 ms)
Relay output (device version 151)
Changeover contact, AC 250 V/3 A, DC 24 V/2 A ... 240 V/0.22 A
digital switching output
(device versions 152 and 153)
DC 24 V ext./50 mA or DC 20 V int./10 mA
Operation in generator mode
(monitored internally)
Integrated brake transistor
external brake resistors: (
^ 11−1 )