MK-100 JCS Tile Saw Revision 06/05, Effective Date June 27, 2005

MAINTENANCE AND TROUBLESHOOTING

°

7. Blade Stops Turning:



































































(D)

Verify circuit breaker at least 20

amps – if not, move to 20-amp

circuit

(A)

Allow motor to cool and

depress motor Overload

Reset Switch

(F)

Check power source voltage is

115V – if not 115v, move to

another circuit

(B)

Verify all plugs fully installed

(C)

Check Ground Fault Circuit

Interrupter (GFCI) tripped

(E)

Verify circuit breaker not tripped

If tripped, reset once

Return to

MK Diamond

for Repair

(G)

Return to MK Diamond


If less than 20

Amps move saw

to 20 Amp circuit

Overload

Reset Switch

If motor does not

start, go to Step B

Verify all plugs

connected

If all plugs connected,

go to Step C

If not tripped, or
If re-trip occurs,

Go to Step D

Reset once

if tripped

If circuit 20 Amp

or greater

go to Step E

Check Breaker

20 Amps

or greater

If tripped, reset

once if trips again,

go to step F

If circuit breaker

not tripped

go to Step F

Check Breaker

tripped

If circuit breaker

not tripped

go to Step F

Check for

correct circuit

voltage