SETUP:

Before powering or starting, check for damage that could prevent this equipment from proper operation or

performing its intended function. Check for binding and alignment of moving parts. Check for damaged,

broken, or missing parts.

Verify the trigger switch, locking button is in the "RELEASE" position.

Before connecting the BX-3 to a power supply, be sure the voltage, cycle and phase of the job site power

source meet the requirements of TABLE 3

VOLTAGE:

115v

CYCLE:

60hz

PHASE:

single phase

TABLE 3

If using an extension power cord, make sure the length and wire gauge corresponds to the requirements

listed in TABLE 1 on page 7. An extension power cord that is too small in wire gauge (diameter), or too

long in length, will cause the motor to overheat and could cause premature failure.

Use an approved Ground Fault Circuit Interrupter (GFCI)

Do not cover the motor vents as this could lead to motor overheating.

Portable Generator:

If using a portable generator to provide power, ensure the generator meets the following minimum

requirements:

8 kW

120/240 volts

66.7/33.3 amps

Single Phase

Pre-start Inspection:

The pre-start inspection should be performed before beginning any job.

NOTE: In order to avoid breaker tripping, a 20-amp circuit breaker should be used.

If the Diamond Blade shows signs of fatigue cracking, replace the blade before starting work.

(B)

Inspect Wooden Strip for

Excessive Grooves

(C)

Movable Cutting Table

Moves Freely

(A)

Inspect Blade for Damage – Verify

Blade Correct for Material Being Cut

(E)

Inspect Motor Air Filter for

Cleanliness

(D)

Inspect for Damage

(F)

Verify Trigger Switch Unlocked

Ease of Movement

(See Maintenance Section

if Problems Arise)

Cracks

Replace if Excessively Grooved

(See Maintenance Section

if Problems Arise)

Inspection

Points

Check for Cleanliness

(See Maintenance Section)

Underside of Handle

Trigger Switch

(Push to Unlock)

Trigger Lock

(Push to Lock)

BX-3 SETUP