Bx-3 troubleshooting, Troubleshooting – MK Diamond BX-3 User Manual

Page 27

Advertising
background image

27

TROUBLESHOOTING:

Verify the Lockable Switch is unlocked and the saw is disconnected from the power source before

performing any troubleshooting procedure.

1. Motor Stops Turning:

2. Blade Will Not Cut Properly:

(A)

Verify all Plugs Fully Connected

If Connected, go to Step B

(B)

Check Ground Fault Circuit

Interrupter (GFCI) Tripped

(C)

Verify Circuit Breaker is

20 Amp or Greater

(E)

Verify Source Voltage

is 115 Volts

(D)

Verify Circuit Breaker

Not Tripped

(B)

Check for Proper Rotation

(A)

Check for Smoothness

or “Glazing”

(D)

Verify Blade Correct for

Material Being Used

(C)

Ensure Blade

Core Not Bent

If Rotation

Correct, go

to Step C

If not “Glazed,

go to Step B

Verify Connected

If GFCI Tripped,

Reset and Restart

BX-3 once

If GFCI not Tripped,

go to Step C

If 20 Amp

Or Greater,

go to Step D

If Less than

20 Amps,

Switch to 20

Amp Breaker

If not

Tripped,

go to Step E

If Breaker Tripped,

Reset once -

Attempt Restart

If Circuit is

not115 Volts,

Change Circuit

If Circuit is 115

Volts, go to

Step F

If Rotation

Not Correct,

Reposition Blade

If “Glazed,” Dress

(See Blade Dressing)

If Core Not

Bent, go to

Step D

If Core Bent,

Change Blade

If Blade

Correct, go

to Step E

Contact Place of Purchase or

MK Diamond (800 421-5830)

To Verify Blade

BX-3 TROUBLESHOOTING

Advertising