Accessories, High pressure filter kit, Accessories 69 – MTS Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2-30 User Manual

Page 69: High pressure filter kit 69

Advertising
background image

High Pressure Filter Kit

Model 505G2.20 - 505G2.30 SilentFlo™ HPU

Accessories

69

Accessories

Contents

High Pressure Filter Kit 69

Replacing the Pressure Line Filter Element 70

Accumulator Kit 71

Commoning Kit 73

Caster Kit 75

High Pressure Filter Kit

This section describes how to install the high pressure filter kit (part number
054-728-8XX).

To install the high pressure filter kit:

1. Ensure that system hydraulic pressure has been reduced to zero before

proceeding. To do this, turn off the hydraulic power unit and exercise the
actuator until it stops moving.

2. Remove the hose assembly and adapter connecting the high pressure port on

the manifold assembly to the high pressure output port.

3. Connect the 45° elbow to the output of the filter assembly. Connect the

straight tube to the input of the filter assembly.

High Pressure Filter Components

4. Connect the elbow to the high pressure port on the control manifold, and

connect the tube assembly to the elbow.

5. Mount the filter assembly and straight adapter to the tube assembly.

Control
Manifold

O-Ring

Adapter

Elbow

Filter Support

High Pressure
Output Port

High Pressure Hose

45° Elbow

High Pressure Port

Check
Valve

Reducer

Filter

Advertising