MTS SWIFT 30 Sensor User Manual

Page 103

Advertising
background image

Road Simulator

SWIFT 30 Sensors

Installing the Transducer

103

8. Attach the appropriate cables from the connector housing or one cable from

the slip ring to the TI or data acquisition.

A. Connect the cable from the Load connector on the connector housing,

or from the slip-ring connector, to the transducer connector on the slip-
ring daughter board of the TI box(es).

B. If used, connect the cable from the Accel connector on the connector

housing to your data acquisition device.

C. Connect the cables from the Shunt A and Shunt B connectors on the

connector housing or the slip-ring bracket to the Shunt A and Shunt B
connectors on the TI box(es)

D. Secure the cables to the lateral strut of the road simulator so that it will

not become damaged during testing.

Be sure to leave enough slack for the full range of movement of the
simulation fixture.

9. Connect a 12 V DC power supply to the TI.

You may need to first convert from 120 or 240 V AC to 12 V DC.

10. Connect the data cable from the TI to the data recorder or your test control

system.

There is one cable per channel of data from the TI to the data recorder.

Advertising