SWIFT 30 Sensors

138

Troubleshooting

A two-time-per-revolution

of tire signal is showing up

when the vehicle is driving
straight on a flat surface.

Gain settings: Verify that the TI electronics

calibration file gain settings have not been

modified. Using the TIXFER utility, upload the
current TI settings and compare them to the

original gain setting on the disk provided.

Bridge Failure: If a single bridge is failing due

to overstress, overload induced crack, and so on,

the results could appear as this type of output.
To verify that this is the cause, use the TIXFER

utility to upload the current TI settings after a

zeroing procedure, and record all bridge zeros.
Load the transducer for several cycles, without

inducing heat (drive vehicle for a few cycles but

do not use excessive brake heating). Rezero the
TI electronics. Use TIXFER to upload the new

zero values. Compare them to the previously

recorded zero values. These values should not
change by more than 0.01 to 0.03 for two zeroes

done at the same conditions, on the same

transducer. If the changes are much larger,
remove the transducer from vehicle and contact

MTS.