Ti jumpers, Ti jumpers 42 – MTS SWIFT 30 Sensor User Manual

Page 42

Advertising
background image

SWIFT 30 Sensors

42

Transducer Interface

Hardware Overview

TI Jumpers

The transducer interface uses circuit board jumpers to establish certain
parameters and make use of various electronic functions. These jumpers are set at
the factory, and should not be reset. The following table is for reference only.

TI PWB Jumper Locations

J

UMPER

S

ETTING

F

UNCTION

X1

1–2

2–3

Excitation setup for shunts FX1, FY1, FY4, and FZ2.

Sets up – (minus) excitation for shunts FX1, FY1, FY4, and FZ2.

Sets up + (plus) excitation for shunts FX1, FY1, FY4, and FZ2.

X2

1–2

2–3

Excitation setup for shunts FX2, FY2, FY43 and FZ1.

Sets up – (minus) excitation for shunts FX2, FY2, FY43 and FZ1.

Sets up + (plus) excitation for shunts FX2, FY2, FY43 and FZ1.

X4

removed

Not used for TI applications (Standard setting).

X5

installed

removed

Enables the ability to download new code to the block of FLASH
RAM where the boot code is stored.

Disables the ability to download new code to the block of FLASH
RAM where the boot code is stored (Standard setting).

X6

installed

removed

Boots to the FLASH memory down-loader.

Boots to the Transducer Interface software (Standard setting).

X2

X1

X4

X5

X6

S20-13