PagE 28 — DCa20SPxu2 SERVPRO

®

• operation and parts manual — rev. #0 (09/23/13)

inspectiOn/setup

refueling procedure:

1.

level tanks — Make sure fuel cells are level with the

ground. Failure to do so will cause fuel to spill from the

tank before reaching full capacity (Figure 19).

Figure 19. Only Fill on Level Ground

Warning

diesel fuel and its vapors are dangerous

to your health and the surrounding

environment. Avoid skin contact and/or

inhaling fumes.

Caution

alWaYs place trailer on firm level ground before

refueling to prevent spilling and maximize the amount

of fuel that can be pumped into the tank.

Level Ground

Unlevel Ground

=

Level Ground

Unlevel Ground

DO NOT fill on
unlevel ground

!

!

Lik

e it

ne

ver

even

ha

pp

en

ed

.

R

SER

VPR

O

R

NOTICE

onlY use #2 diesel fuel when refueling.

2. Remove fuel cap from filler neck and fill fuel tank

(Figure 20).

3.

never overfill fuel tank — It is important to read the

fuel gauge when filling trailer fuel tank.

do not wait

for fuel to rise in filler neck (Figure 20).

Figure 20. Full Fuel Tank

Figure 21. Fuel Expansion

Coolant (antiFreeze/summer Coolant/

Water)

ISUZU recommends antifreeze/summer coolant for use in their

engines, which can be purchased in concentrate (and mixed

with 50% demineralized water) or pre-diluted. See the

isuzu

engine owner’s manual for further details.

Caution

do not overFill fuel system. Leave room for fuel

expansion. Fuel expands when heated (Figure 21).

Warning

If adding coolant/antifreeze mix to the

radiator,

do not remove the radiator cap

until the unit has completely cooled. The

possibility of

hot! coolant exists which can

cause severe burns.