Omnitron Systems Technology iConverter 1-Module Power Chassis User Manual

Page 4

Advertising
background image

Page 6

Page 7

3.0 SPECIFICATIONS

Model Number

8240-1 /

8241-1

8240-2 /

8241-2

8242-1 /

8243-1

8242-2 /

8243-2

8242-9 /

8243-9

Module Capacity

1

Power Supply Type

Wall Power

Supply

Tabletop

Power Supply

Tabletop Power

Supply

Tabletop

Power Supply

User Supplied

Power Supply

Connector

US Plug

IEC 320

Socket

US Power Cord

IEC 320

Socket

3 Position

Terminal

Power Requirements

120VAC / 60Hz

0.2A @

120VAC

100 to 240VAC

50 / 60Hz

0.2A @

120VAC

120VAC / 60Hz

1.0A @

120VAC

100 to 240VAC

50 / 60Hz

1.0A @

120VAC

20 to 60VDC*

0.6A Max

Dimensions

W: 3.8” x D: 5.5” x H: 1.0”

W: 3.8” x D: 6.0” x H: 1.0”

Weight

1.5 lbs.

Compliance

UL, CE, FCC Class A, NEBS Level 3

Temperature

Standard Operating

Wide Operating

0 to 50

o

C

-40 to 60

o

C

Humidity

5 to 95% (non-condensing)

Altitude

-100m to 4,000m

MTBF (hrs)

250,000

100,000

260,000

260,000

2,700,000

4.0 CUSTOMER SUPPORT INFORMATION

If you encounter problems while installing this product, contact Omnitron Technical

Support:

Phone:

(949) 250-6510

Fax:

(949) 250-6514

Address:

Omnitron Systems Technology, Inc.

38

Tesla

Irvine, CA 92618, USA

Email:

[email protected]

URL:

www.omnitron-systems.com

040-08240-001J 10/13

* Effective range is 18 to 60VDC when using a module without dying gasp support.

WARNING: Note the wire colors used in making the positive, negative and ground connections.

Use the same color assignment for the connection at the circuit breaker.
Connect the power wires to the circuit breaker and switch the circuit breaker ON. If any modules

are installed, their Power LED should indicate the presence of power.
If installing with the NEBS Mounting Kit for 8242-9 and 8243-9 models, secure the grounding

wire to the ground lug. See Figure 3 for the location of the grounding lug.

Fig. 3 Rear of 1-Module Power Chassis,

Models 8242-9 and 8243-9 with DC Power Connector

NEVER ATTEMPT TO OPEN THE CHASSIS OR

SERVICE THE POWER SUPPLY. OPENING THE

CHASSIS MAY CAUSE SERIOUS INJURY OR DEATH.

THERE ARE NO USER REPLACEABLE OR

SERVICEABLE PARTS IN THIS UNIT.

WARNING!!!

Advertising