Omnitron Systems Technology FlexPoint Powered Chassis 14-slot power-redundant chassis User Manual

Page 4

Advertising
background image

4

Omnitron Systems Technology, Inc.

CONTROLS AND INDICATORS

LEDs Display:
The Powered Chassis features two LEDs on the left front of the chassis, these
LEDs display the status of the two power supplies.

Function

Color/State

Description

Top LED

Yellow / ON

Power OK in right power supply

Bottom LED

Yellow / ON

Power OK in left power supply

Note: Left/right direction as viewed from the front of the chassis.

SITE PREPARATION REQUIREMENTS

1. Power: Two power outlets should be available within 5 feet of the unit.
2. The operating temperature of this equipment is 0-50 degrees C. If installed

in a closed or multi-unit rack assembly, the operating ambient temperature
of the rack must not exceed the maximum rated 50 degrees C temperature.

3. Installation of the equipment should be such that the air flow in the front

and back of the unit is not compromised or restricted.

4. Never use this equipment to carry any weight except its own, never use it as

a shelf to support weight of other equipment.

5. Installing this equipment into a rack in such a way as to make it unstable

may cause injury or death. Always make sure that the rack you are installing
this equipment into is properly secure, stable, balanced and designed to
carry the weight and weight distribution of this equipment.

6. When rack-mounting this equipment, the rack should be appropriately

earth-grounded.

7. This equipment requires 110VAC / 1.5 Amps at 60Hz (or 220VAC / .75 Amps

at 50Hz) power per outlet (two outlets are required) to a combined total of
110VAC / 3.0 Amps at 60Hz (or 220VAC / 1.5 Amp at 50Hz). Appropriate
overloading protection should be provided on all AC power source outlets
utilized.

Omnitron Systems Technology, Inc.

UNPACKING

a. Visual Inspection: Inspect equipment in order to detect any physical damage.

Any evidence of damage should be noted and reported immediately.

INVENTORY

Review contents, the following items should be included:

(1)

FlexPoint Powered Chassis unit.

(2)

Power supplies (2 for model 4395, 1 for model 4396).

(14) L shape tabs.
(14) Screws
(1)

User’s manual (this document).

Please note any missing items or discrepancies and report them immediately.

INSTALLATION

Cabling and Power-Up:

a. Plug the two power cords into two appropriate AC wall outlets. The two LED

power lights should turn ON.

b. Attach the L shaped tabs to the FlexPoint units to be inserted into the chassis,

Secure the FlexPoint module using the enclosed screws.

c. Save the unused tabs in a safe place or secure them to the chassis’ unused

slots.

POWER SUPPLY REPLACEMENT

WARNING

NEVER ATTEMPT TO OPEN OR SERVICE THE POWER

SUPPLY UNIT. OPENING THE POWER SUPPLY UNIT

MAY CAUSE SERIOUS INJURY OR DEATH.

5

Advertising