F

aults

Solutions

T

HE UNIT DOES NOT LIT UP

T

HE DRIVE RATE IS INCORRECT

F

LOW RATE TEST

T

HE UNIT COMES ON AS NORMAL

,

BUT THERE IS NO

RESPONSE FROM THE

MS

ACTUATORS

A

REA COUNTER READING INCORRECT

Check

- unit/power supply connections

- fuses supply line

Check

- connection on unit

- sensor magnet clearance

- magnet rotation

- sensor wire continuity

(100Ω ± 10)

- 100-m coefficient

Check

- c

alibration factor

Carry out a new calibration test

Check

-

Fuses

Check

-

connection / machine

- working width

- Carry out another test over 100 metres.

- programmed flow rate

Informations