Troubleshooting

Error and warning codes

If an error occurs in the electronics, the color of the status LED changes from green to red
and the background illumination of the digital display changes from white to red. A status
LED flashing red and green displays an error or warning code, as outlined below:

• E-code for errors

In the event of an error message, the measured value is unreliable.

• W-code for warnings

In the event of a warning, the measured value is still reliable.

Error Codes

Code

Explanation

E011

Device configuration faulty

E012

Error in measurement or underrange/overrange

E013

Error at heating resistor

E015

Error in EEPROM

E019

Power supply has undervoltage/overvoltage

E020

Error in Flash

E021

Internal memory error

E022

USB power supply

E027

Characteristic does not suit medium

E042

Output current can no longer be generated. Possible cause:
analog output not connected or open circuit.