Rockwell Automation 839E Solid-State Flow Sensors User Manual

Page 25

Advertising
background image

839E Solid-State Flow Sensors User Manual

Pub #10000004735 Ver 03, May 2012

23

Warning Codes

Repair

Bulletin 839E flow switches are not repairable.

Disposal

Please pay particular attention to the local disposal regulations of your country. Ensure the
materials of the device components are separated and processed accordingly.

Change status (release)

The release number on the nameplate and in the Operating Instructions indicates the
change status of the device: XX.YY.ZZ (example 01.02.01).

Code

Explanation

W107

Simulation active

W202

Flow outside the sensor range

W209

Device start-up

W210

Configuration modified

W212

Sensor signal outside the permitted range

W250

Number of switch cycles exceeded

W260

Value for High Flow (HIF) and Low Flow (LOWF) faulty

W270

Short-circuit and overload at output 1

W280

Short-circuit and overload at output 2

W432

Values for high flow (HIF) or low flow (LOWF) could not be
determined with certainty. The device can be operated,
however.

XX

Change in the main version.
Compatibility no longer provided. Device and Operating Instructions
change.

YY

Change in functionality and operation.
Compatibility provided. Operating Instructions change.

ZZ

Troubleshooting and internal modifications.
Operating Instructions do not change.

Advertising