Original instructions, Electrical installation, Connections – Rockwell Automation 440L GuardShield Type 4 and Remote Teach User Manual User Manual

Page 17: Guardshield remote teach receiver bracket, Power supply, Edm connection

Advertising
background image

R

GuardShield™ Safety Light Curtain User Manual

15

Original instructions

Optional Middle Mounting Bracket (440L-AF6108)

Figure 10: Middle mounting brackets

Note: Middle mounting brackets should be used in vibration

applications for protective heights of 1120 mm and larger.

GuardShield Remote Teach Receiver Bracket

Figure 11: Remote teach receiver bracket

Electrical Installation

Connections

Power Supply

The external voltage supply (+24V DC) must meet the requirements
of IEC 61496-1. In addition, the following requirements have to be
fulfilled:

• A short-term power failure of 20 ms must be bridged by the

power supply.

• The power supply has double insulation between the primary

and the secondary side.

• The power supply is protected against overload.

• The power supply corresponds to the guidelines of the EWG

(industrial environment).

• The power supply corresponds to the Low Voltage Directives.

• The grounded conductor of the power supply device must be

connected to a grounded conductor PE.

• The maximum deviation of the voltage levels is 24V DC +/-

20%.

EDM Connection

Figure 12: Connecting the contact elements to the EDM

Figure 13: Connecting the reset button/restart button

49.2 (1.93)

40.2

(1.58)

62

(2.44)

24

(0.94)

30 (1.18)

20 (0.78)

Double insulation

This part of the insulation provides

supplementary insulation against

hazardous voltage levels.

Motor, etc.

Hazardous voltage level

Basic insulation

Hazardous voltage

level

Hazardous voltage

level

Reinforced

insulation or

double insulation

Unit 1

Power Supply

Unit 2

Output (pink and

grey)

Basic insulation

(See note.)

Basic insulation

0V (blue)

+24V (brown)

K1

K1

K2

K2

Guard
Shield

24V

Pin 4

5

6

K1

K2

k2

k1

Contactor

Contacts

Contactor

Coils

Not available for GuardShield with ArmorBlock
Guard I/O connectivity.

IMPORTANT

Reset/restart button

Pin 8

24V

Advertising