System Module Power Specifications
1
1394C-SJT05-D, -SJT10-D, and -SJT22-D system modules are limited to four contactor cycles per minute.
2
Peak inrush current is limited by an internal 80 ohm resistor. The 8A peak inrush current for all Series C system
modules will experience no more than a 40A peak loss (less 1 ms).
3
The peak power output rating is based on a current limit of 105% of two times the rated continuous current output
for 600ms or the rated peak power output for a duration equal to the equivalent watt-seconds.
The:
For the 1394C-SJT05-D is:
For the 1394C-SJT10-D is:
For the 1394C-SJT22-D is:
Rated AC input voltage
324-528V AC, 50/60 Hz
Three phase
324-528V AC, 50/60 Hz
Three phase
324-528V AC, 50/60 Hz
Three phase
AC input current (A
rms
)
6.5A
13.0A
28.6A
Peak inrush current
1, 2
8A
8A
8A
Line loss ride through
20 ms
20 ms
20 ms
Nominal bus output voltage
530/680V dc
530/680V dc
530/680V dc
Continuous power output
4/5 kW
8/10 kW
17/22 kW
Peak power output
3
28 kW
28 kW
136 kW
Efficiency
99%
99%
98%
Weight
10.68 kg (23.5 lb)
10.68 kg (23.5 lb)
12.9 kg (28.5 lb)
Continuous current output (A
dc
)
7.36A
14.73A
33.8A
Intermittent current output (A
dc
)
15.0A
29.46A
200A
Capacitance
220
µ
F
345
µ
F
660
µ
F
Inductance
1000
µ
H
750
µ
H
500
µ
H
Internal shunt resistor
200W continuous, 40,000W peak (two second maximum on
time)