Power specifications, System module power specifications – Rockwell Automation 1394 SERCOS Interface Multi-Axis Motion Control System Installation Manual User Manual

Page 106

Advertising
background image

Publication 1394-IN002B-EN-P — February 2004

A-2

Specifications and Dimensions

Power Specifications

This section contains power specifications for the 1394 SERCOS
interface system.

System Module Power Specifications

1

1394C-SJT05-D, -SJT10-D, and -SJT22-D system modules are limited to four contactor cycles per minute.

2

Peak inrush current is limited by an internal 80 ohm resistor. The 8A peak inrush current for all Series C system
modules will experience no more than a 40A peak loss (less 1 ms).

3

The peak power output rating is based on a current limit of 105% of two times the rated continuous current output
for 600ms or the rated peak power output for a duration equal to the equivalent watt-seconds.

The:

For the 1394C-SJT05-D is:

For the 1394C-SJT10-D is:

For the 1394C-SJT22-D is:

Rated AC input voltage

324-528V AC, 50/60 Hz

Three phase

324-528V AC, 50/60 Hz

Three phase

324-528V AC, 50/60 Hz

Three phase

AC input current (A

rms

)

6.5A

13.0A

28.6A

Peak inrush current

1, 2

8A

8A

8A

Line loss ride through

20 ms

20 ms

20 ms

Nominal bus output voltage

530/680V dc

530/680V dc

530/680V dc

Continuous power output

4/5 kW

8/10 kW

17/22 kW

Peak power output

3

28 kW

28 kW

136 kW

Efficiency

99%

99%

98%

Weight

10.68 kg (23.5 lb)

10.68 kg (23.5 lb)

12.9 kg (28.5 lb)

Continuous current output (A

dc

)

7.36A

14.73A

33.8A

Intermittent current output (A

dc

)

15.0A

29.46A

200A

Capacitance

220

µ

F

345

µ

F

660

µ

F

Inductance

1000

µ

H

750

µ

H

500

µ

H

Internal shunt resistor

200W continuous, 40,000W peak (two second maximum on
time)

No internal Shunt Resistor

Advertising