Rockwell Automation 1394 SERCOS Interface Multi-Axis Motion Control System Installation Manual User Manual
Page 78

Publication 1394-IN002B-EN-P — February 2004
3-24
Connecting Your 1394 SERCOS Interface System
3. Gently pull on each TB1 wire to make sure it does not come out
of its terminal. Re-insert and tighten each loose wire.
4. Insert the first connector plug (TB1) into the front-most mating
half under the axis module.
5. Connect the appropriate thermal switch control wires to the
second connector plug (TB2) in the kit (pins 3 and 4) and tighten
the TB2 screws. Refer to Appendix B for thermal switch
interconnect diagrams.
6. Connect the appropriate brake control wires to the second
connector plug (TB2) in the kit (pins 1 and 2) and tighten the
screws. Refer to Appendix B for brake interconnect diagrams.
7. Gently pull on each TB2 wire to make sure it does not come out
of its terminal. Re-insert and tighten each loose wire.
8. Insert the second connector plug (TB2) into the rear-most mating
half under the axis module.
9. Go to Wiring the Relay Outputs Connector on page 3-25.
ATTENTION
!
To avoid damage to your motor, monitor the
thermal switch for overheat conditions.