System module input power pin-outs, Scanport adapter – Rockwell Automation 1394 SERCOS Interface Multi-Axis Motion Control System Installation Manual User Manual
Page 43

Publication 1394-IN002B-EN-P — February 2004
1394 SERCOS Interface Connector Data
2-11
System Module Input Power Pin-outs
The following table provide the signal descriptions and pin-outs for
the system module input power connections.
For the location of 1394C-SJT05-D and -SJT10-D input connectors,
refer to Figure 2.1 on page 2-2. For the location of 1394C-SJT22-D
input terminal block, refer to Figure 2.2 on page 2-3. Refer to Logic
Power Input Specifications on page 2-20 for signal specifications.
Figure 2.7
1394C-SJTxx-D Input Power
SCANport Adapter
This port allows you to connect a SCANport device, such as a Human
Interface Module (HIM), to the 1394 SERCOS Interface system. Refer
to figures 2.1 and 2.2 for SCANport location. Refer to the 1394
SERCOS Interface Integration Manual (publication 1394-IN024x-EN-P)
for information on using the HIM.
Pin
Description
Signal
W1
Logic power input
W1
W2
W2
U
Three-phase main input power
U
V
V
W
W
PE
Chassis Ground
DC+
External Shunt Connections
DC+
INT
INT
COL
COL
U V W
COL INT DC+
W1 W2
P E
1394C-SJT05-D and -SJT10-D
Input Power Connectors
1394C-SJT22-D
Input Power Terminal Blocks