Configurable Flowmeter Module

6

Publication 1771ĆIN043B-EN-P - July 2002

Place your module in any slot of the I/O chassis except for the
extreme left slot. This slot is reserved for processors or adapter
modules.

Use of data table

2Ćslot addressing

1Ćslot addressing

1/2Ćslot addressing

Input Image Bits

8

Place the CFM module in any Place the CFM module in any

Output Image Bits

8

Place the CFM module in any

module group with any 8Ćbit or

Place the CFM module in any

module group with any 8Ćbit

no restrictions

Read Block Words

41 max

module group with any 8Ćbit or

block transfer module.

module group with any 8Ćbit,

16Ćbit or block transfer module.

no restrictions

Write Block Words

60 max

b oc a s e od e

6 b o b oc a s e od e

Key the Backplane

Connector

Observe the following
precautions when inserting or
removing keys:

insert or remove keys with
your fingers

make sure that key placement
is correct

Incorrect keying or the use of a
tool can result in damage to the
backplane connector and possible
system faults.

!

ATTENTION

Position the keying bands in the backplane connectors to correspond

to the key slots on the CFM module.

19808

Place the keying bands:

S between 2 and 4

S between 6 and 8

The CFM module's printed circuit board is slotted in two places on the

rear edge. These slots are intended to mate with the plastic keying bands

supplied with the I/O chassis.

Determine CFM Module

Placement